Maintenance
How to solve the problem of high vacuum degree in the suction pipe of the main pump of the WY20 excavator?
1. The causes of the vacuum degree at the suction port of the main oil pump
The LR6105 diesel engine adopted on the WY20 hydraulic excavator is produced by the Second Engine Factory of the First Tractor Corporation by introducing the technology of the British Licardo Company. Its high-pressure pump, diesel filter and oil filter are all located on the left side. When designing, considering the maintenance and upkeep of the diesel engine, the high-pressure pump, diesel filter and oil filter were placed at the front of the excavator. The crankshaft output end was on the left side of the excavator, while the hydraulic oil tank was on the right side of the excavator platform. As a result, the suction pipe was 2.5 meters long and had three bends, which increased the suction resistance of the main oil pump. Although the oil tank was preloaded (0.05MPa), it was still difficult to counteract the pressure drop caused by its resistance, thus creating a vacuum at the pump port
For the reasons mentioned above, only by shortening the length of the suction pipe of the main oil pump and reducing the pipe resistance can the vacuum degree at the suction port of the main pump be eliminated.
2 Solution
The objective to be achieved is to reduce the vacuum degree of the main pump suction pipe, making the vacuum degree value lower than 0.005MPa.
The solution is as follows: The original positions of the hydraulic oil tank and diesel tank remain unchanged, and the upper platform structure does not make major alterations. Only the installation direction of the diesel engine on the excavator is reversed by 180°, and its bracket is slightly modified to shorten the length of the main pump suction pipe from the original 2.5m to 0.6m
3 Conclusion
The improved prototype was tested on the construction site and it was found that:
When the oil tank is pre-pressurized, the vacuum degree at the suction port of the main pump is zero under the four working conditions: the valve is in a neutral position, the boom lifting and rotation combined action, the walking and rotation combined action, and the four oil cylinders combined action.
(2) When the oil tank is not pre-pressurized, the maximum vacuum degree under the above four working conditions is 0.004MPa. It can be seen that the vacuum degree at the suction port of the main pump of the improved prototype has significantly decreased, reaching the predetermined goal.
Related articles
- "Drill Under the Vehicle, Refine the Details" - Shantui Wood Plate Loader, born for wood p
- Sany Heavy Industry: Thousands of Questions on Maintenance and Repair: Air Mixed into the Hydraulic
- Over the past ten years, with 45 models, XCMG's extraordinary innovative journey of rotary drilling
- Case: CX380C: Only after enduring the "harsh winter" can there be a spring!
- The intelligent prestressing system for anchor bolt trolleys of CRRC Heavy Industry has been success
- Caterpillar's National IV products are revealed for the first time
- Xingbang Heavy Industry: "Debut" from the factory! Watch the "All-Rounder Armor"
- How to install and adjust the speed control motor of the CAT325L excavator
- Detailed Analysis of Faults in the Vibration System of Road Rollers
- Adhere to the four "don 'ts" to ensure a long service life of diesel engines

