Maintenance
Analyze the common faults of the gas control valve of the W4-60C excavator
In the dynamic gas circuit system of the W4-60C excavator, a gas control valve is installed between the air pump and the air storage tank. Its main function is to separate oil and water from the compressed air, filter red dust and impurities in the compressed air, prevent the compressed air in the air storage tank from flowing back to the air pump, and ensure that the gas pressure remains stable within the range of 0.490-0.637MPa. The maximum pressure does not exceed 0.784MPa. The following faults often occur during use:
The pressure regulating valve is leaking air due to the damage of the pressure regulating diaphragm
The pressure regulating diaphragm 6 is a rubber product. Due to its frequent repeated compression by air pressure, repeated arching and resetting actions, and corrosion by gas and moisture, the diaphragm is often damaged. This is the most common fault of this control valve. After the diaphragm is damaged, the compressed gas from the air pump enters the upper part of the pressure regulating valve through the diaphragm instead of entering the air storage cylinder, resulting in the air pressure in the air storage cylinder not being able to rise. At this time, the temperature of the pressure regulating valve is prone to rise, and the brake system pressure gauge indicates insufficient air pressure. A leakage sound can be heard at the pressure regulating valve.
2. The control valve housing is cracked
The valve housing is composed of three parts: upper, middle and lower, which are respectively connected by screws. As the shell is made of aluminium, when it is disassembled or reassembled, if the method of removing and installing screws is improper, the shell is prone to cracking. When disassembling or installing screws, they should be tightened or loosened diagonally and in multiple steps to ensure that the force on the mating surface of the shell remains consistent, preventing damage due to uneven force.
- Pre
Analysis of Fault Characteristics of Construction Machinery and Fault Diagnosis Techniques
2. Empirical diagnosis of faults in construction machineryDi...
- Next
Precautions and suggestions for the use and maintenance of loaders in winter
The harsh and cruel winter climate is undoubtedly a test for...
Related articles
- 1.36 degrees per kilometer, a new model for the operation of new energy heavy-duty trucks driven by
- Allison Transmission has joined hands with Liugong to facilitate the efficient operation of the Dana
- With multi-scenario applications and diversified adaptation, the Panhu Electric Motorcycle ecosystem
- Accelerate the cultivation and opening of scenarios, and empower the value transformation of scenari
- "Victory in six days!" The Oukejia electronic control system helps domestic large-scale co
- "I'll cover your coal!" " The mining area tycoon - XCMG XDE240 double-axle rigid mini
- Small in size but capable in ability, the Shanggong low headroom cast-in-place pile drilling rig mak
- Troubleshooting methods for the "equal gear" fault of the TY220 bulldozer
- Analysis and Treatment of the Causes of Easy fracture of Engine Crankshafts
- Repair of Abnormal noise Fault of the rear axle differential of XCMG ZL50 Loader